FSTest

ATP Hygiene Monitor

MC200 Series

ATP Hygiene Monitor MC200

Product Overview

The design of FSTest ATP Fluorescence Detector is based on the principle of firefly luminescence, in which the luciferase-fluorescein system can be made use for rapid detection of adenosine triphosphate (ATP). The detector can release ATP from living microorganism by lysing the cell wall, and then the free ATP binds to the fluorescence under the action of luciferase to produce luminescence, and the fluorescence of the substance is proportional to the number of microorganisms on the sample. Thus, hygiene can be evaluated by measuring the intensity of the fluorescence signals.
Features
  • Easy To Carry : Satisfy the requirements from varied detection environments.
  • High Accuracy : Limit of detection is 1x10-16mol ATP
  • Rapid Detection : Complete the detection in 10 seconds.
  • Humanized Design : Double operation modes (touch or key). Unqualified results are prompt automatically.
  • Low Energy Consumption : Built-in lithium battery, sustainable for 16 hours, standby for more than 1200 hours.
  • Automatic Calibration : Equipped with automatic calibration light source and temperature detection system, adapt to the change of detection environment automatically.

  • The advantages of FSTest ATP VS Other Brand' ATP are as follows


    Items FSTest ATP Other Brands' ATP
    Input ways Capacitive touch screen (MC200), better operation experience. Most devices are operated through button controls
    Easy to clean Featuring a detachable detection chamber that users can disassemble for cleaning. Certain competing products feature non-detachable detection chamber. Which cannot be cleaned and may lead to inaccurate test results
    Simplified Interface More intelligent, direct selection the sample type and test sample (including judgement standards) by clicking on the touch screen. More complicated, need to return to the home-page to retrieve the sample type and test sample (including judgement standards).
    Personal Response Adjustment of the sample judgement range by user according to the actual situation, convenient for customers who want establish their own standards. Users cannot adjust the judgement range and need to return the device to the manufacturer for updates
    Measure Range 0~999999 RLUs 0~99999 RLUs or 0~999999 RLUs
    Sensitivities Level 1x10-16mol ATP 1x10-15mol ATP or 1x10-16mol ATP

    Product Parameters


    Cat No. MC31.3165.5
    Dimension 19.4cm(L)x9.7cm(W)x3.3cm(H)
    Net Weight 350g
    Screen 3.5-inch
    Initializing time 15s or 30s
    Testing Time 10s
    Detection Range 0~999999 RLUs
    Precision 1x10-16mol ATP
    Dectection Error ±5% or ±5 RLUs
    Wireless Communication Wifi, Bluetooth and USB
    Storage Volume More than 20000 Results
    Battery 5200mAh, Li-ion, rechargeable
    Power Supply 5V/2A, USB/TYPE-C